U120B, ANSI 52-5 Glass Insulator Ball & Socket Disc Suspension (LXP-120) — 120kN Toughened Glass Insulator for High-Voltage Overhead Transmission Lines
The U120B, ANSI 52-5 Glass Insulator Ball & Socket Disc Suspension (LXP-120) is a high-strength, ball-and-socket type disc suspension insulator with a rated mechanical failing load of 120kN (25,000 lbs).
Manufactured by TCI Insulators, this insulator is engineered for insulation and mechanical support of high-voltage overhead transmission lines, including 110kV, 132kV, 220kV, and higher voltage systems.
It combines high-strength toughened glass with hot-dip galvanized steel hardware, delivering reliable performance in transmission towers, substations, railway electrification systems, and heavy-load line applications.
The U120B designation follows the IEC naming convention: U = disc suspension insulator, 120 = rated mechanical failing load of 120kN, B = ball-and-socket coupling type.
The ANSI 52-5 classification corresponds to the ANSI C29.2 standard for wet-process porcelain and toughened glass insulators.
The unit is fully compliant with IEC 60383-1, GB/T 1001.1, and ANSI C29.2, with connection structures conforming to GB/T 4056-2008 (IEC 60120) and BS 3288 Part III.
U120B, ANSI 52-5 Glass Insulator Technical Specifications
Dimensions
| Parameter | Value |
| Diameter (D) | 10 inch (255mm) |
| Spacing (H) | 5 3/4 inch (146mm) |
| Leakage Distance | 12 5/8 inch (320mm) |
| Coupling Size | 16 |
The 146mm spacing provides additional mechanical clearance and flexibility in string design. The optimized aerodynamic umbrella profile with deep concentric ribs effectively prevents water-film formation, reducing flashover risk in heavy rain, fog, and polluted environments.
Mechanical Values
| Parameter | Value |
| Mechanical Failing Load | 25,000 lbs (120kN) |
| Tension Proof | 12,500 lbs (60kN) |
The 120kN mechanical failing load provides exceptional tensile strength to withstand heavy conductor tension, wind loads, ice loads, and dynamic forces in high-voltage transmission lines. Each unit undergoes a routine proof test at 60kN to guarantee reliability.
U120B, ANSI 52-5 Glass Insulator Electrical Values
| Parameter | Value |
| Low Frequency Dry Flashover Voltage | 80kV |
| Low Frequency Wet Flashover Voltage | 50kV |
| Critical Impulse Flashover Voltage, Positive | 125kV |
| Critical Impulse Flashover Voltage, Negative | 130kV |
| Low Frequency Puncture Voltage | 130kV |
The toughened glass dielectric delivers superior insulation capability, withstanding power frequency voltages and impulse surges while maintaining stable performance across varying climatic conditions.
Radio Influence Voltage (RIV) Data
| Parameter | Value |
| Test Voltage RMS to Ground | 10kV |
| Maximum RIV at 1000 kHz | 50μV |
Packing and Shipping Data
| Parameter | Value |
| Net Weight, Approximate | 4.2kg |
U120B, ANSI 52-5 Glass Insulator Key Features
High Mechanical Strength (120kN) — The 120kN rated failing load makes the LXP-120 (U120B, ANSI 52-5) suitable for high-voltage transmission lines, long spans, and heavy-load applications where standard 70kN or 100kN insulators may be insufficient.
ANSI 52-5 Compatibility — Designed to meet ANSI C29.2 requirements, the LXP-120 (U120B) is interchangeable with ANSI 52-5 class insulators, ensuring seamless replacement and compatibility with North American transmission and distribution systems.
Automatic Zero-Value Self-Shattering — When an electrical or mechanical fault occurs, toughened glass self-shatters, leaving the mechanical string intact. Patrol teams can spot defects instantly from the ground without climbing towers or using expensive testing equipment.
Superior Anti-Aging & Weather Resistance — Unlike porcelain or composite materials, toughened glass resists chemical aging, UV radiation, and retains dielectric properties for decades of service.
Longer Spacing (146mm) — The extended 146mm spacing offers greater mechanical clearance and allows for customized string lengths, making it suitable for applications where additional spacing is required without compromising electrical performance.
Flexible Locking Pin Options — The U120B accommodates either W-pin or R-pin locking mechanisms; R-pin is used as the standard configuration unless otherwise specified.
Hot-Dip Galvanized Hardware — The cap and pin are made from hot-dip galvanized ductile iron and forged steel, assembled with high-strength aluminous cement. A stainless steel split pin secures the coupling of units. An optional zinc sleeve (sacrificial anode) is available for heavy-pollution lines.
U120B, ANSI 52-5 Glass Insulator Applications
- 110kV–220kV overhead power transmission lines
- High-voltage transmission towers and substations
- Railway electrification systems
- Heavy-load and long-span transmission projects
- Tension strings and suspension strings
- ANSI-compatible transmission projects
- Industrial power grids and utility networks
Why Choose U120B, ANSI 52-5 Glass Insulator TCI Insulators?
TCI Insulators is a trusted manufacturer of composite and porcelain insulators, serving global utilities and contractors since 2002. With state-of-the-art testing facilities and rigorous quality assurance processes, TCI conducts comprehensive product tests including ultraviolet aging, hardness, flame-retardant, tracking, and leakage current tests according to national and international standards.
Our disc suspension insulator system supports mechanical and electrical loads from 10,000 to 50,000 lbs, available across all voltage levels for both distribution and transmission systems, fully compliant with IEC and ANSI standards.
U120B, ANSI 52-5 Glass Insulator Related Products
- LXP-40 (U40B) Ball & Socket Disc Suspension Insulator — 40kN rated, for 10–35kV lines
- LXP1-70 (U70BS) Ball & Socket Disc Suspension Insulator — 70kN rated, standard spacing for 33–66kV lines
- LXP2-70 (U70BL, ANSI 52-3) Ball & Socket Disc Suspension Insulator — 70kN rated, long spacing for 33–66kV lines
- LXP-100 (U100BL) Ball & Socket Disc Suspension Insulator — 100kN rated, for high-voltage transmission
- Porcelain Disc Suspension Insulators — U40B through U300B IEC class range
- Composite Hollow Insulators — For instrument transformers and circuit breakers
Internal Links:
- TCI Insulators Homepage
- Disc Suspension Insulators
- Toughened Glass Insulators
- Composite Hollow Insulators
- Contact TCI Insulators
External Links:
- IEC 60383-1 — Insulators for Overhead Lines
- GB/T 1001.1 — Insulators for Overhead Lines with a Nominal Voltage Above 1,000 V
- ANSI C29.2 — Wet-Process Porcelain and Toughened Glass Insulators
- IEC 60120 / GB/T 4056 — Ball and Socket Coupling Dimensions
- BS 3288 Part III — Insulator Connections