SFC1-11KV USA Type Cutout Fuse Product
SFC1-11KV USA Type Cutout Fuse – 10-15kV High-Voltage Overhead Line Protection Solution
Product Overview
In electrical distribution, a fuse cutout or cut-out fuse is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads.
The SFC1-11KV USA Type is designed for 10-15kV class systems and is available in 100A and 200A rated current versions.
It provides reliable electrical performance, high breaking capacity, and flexible customisation for various distribution project requirements.
The SFC1-11KV USA Type features a breaking current of 10000A for the 100A version and 12000A for the 200A version.
It offers an impulse voltage of 110kV, power-frequency withstand voltage of 42kV, creepage distance of 250mm, weight of 7kg, and dimensions of 38.5×34.5×10.5 cm.
We make available these fuses in varied specifications to meet the clients’ different preferences in an efficient manner.
All dimensions, electrical ratings, mounting configurations, and fuse link options are customisable upon request.
For complete engineering drawings or specific tolerances, please refer to the original documentation or contact our technical team.
Related internal pages:
Cutout Fuses · High Voltage Fuses · Distribution Transformer Protection · Overhead Feeder Protection · SFC1-11KV Datasheet · Request a Quote · Contact Us
External reference:
Fuse cutout – Wikipedia · Fuse (electrical) – Wikipedia · IEC – International Electrotechnical Commission · IEEE Standards Association · ANSI
SFC1-11KV USA Type Cutout Fuse Technical Specifications
| Specification | SFC1-11KV | SFC1-11KV |
| Rated Voltage (kV) | 10-15 | 10-15 |
| Rated Current (A) | 100 | 200 |
| Breaking Current (A) | 10000 | 12000 |
| Impulse Voltage (kV) | 110 | 110 |
| Power-frequency Withstand Voltage (kV) | 42 | 42 |
| Creepage Distance (mm) | 250 | 250 |
| Weight (kg) | 7 | 7 |
| Dimensions (cm) | 38.5×34.5×10.5 | 38.5×34.5×10.5 |
SFC1-11KV USA Type Cutout Fuse Key Features
- Fuse and Switch Combination – Combines the functions of a fuse and a switch for primary overhead feeder lines and taps.
- Distribution Transformer Protection – Protects distribution transformers from current surges and overloads.
- High Breaking Capacity – Breaking current of 10000A for the 100A version and 12000A for the 200A version.
- Reliable Electrical Performance – Rated for 10-15kV systems with 110kV impulse voltage and 42kV power-frequency withstand voltage.
- Good Anti-Pollution Performance – 250mm creepage distance supports reliable operation in normal and polluted environments.
- Robust Construction – Designed for outdoor installation with a weight of 7kg and compact dimensions of 38.5×34.5×10.5 cm.
- Easy Installation – USA Type design suitable for standard mounting methods on overhead line structures.
- Customisable Design – Dimensions, electrical ratings, mounting configurations, and fuse link options can be customised upon request.
- Reliable and Low Maintenance – Engineered for long-term operation with regular visual inspection and cleaning typically sufficient.
SFC1-11KV USA Type Cutout Fuse Application Scenarios
The SFC1-11KV USA Type cutout fuse is suitable for:
- Primary overhead feeder lines and taps
- Distribution transformer protection
- 10-15kV class overhead distribution networks
- AC overhead power lines
- Pole-mounted installations on wooden, reinforced concrete, and metal poles
- Power distribution networks in normal and polluted areas
- Rural and urban distribution systems
- Industrial and commercial power distribution
- Areas exposed to current surges and overloads
- Vertical or horizontal mounting, subject to project design
Related internal pages:
Overhead Line Protection · Distribution Line Protection · Transformer Protection · Custom Fuse Solutions
SFC1-11KV USA Type Cutout Fuse Standards Compliance
| Standard | Description |
| To be confirmed | Please refer to original documentation or contact technical team for applicable standard compliance. |
| IEC | Additional standards may be available upon request. |
| IEEE | Additional standards may be available upon request. |
| ANSI | Additional standards may be available upon request. |
| GB / DIN / AS | Additional standards may be available upon request. |
External standards references:
IEC · IEEE Standards Association · ANSI · DIN · Standards Australia
Why Choose SFC1-11KV USA Type Cutout Fuse for Your Power Grid?
- High Breaking Capacity – 10000A/12000A breaking current provides reliable protection against current surges and overloads.
- Dual Current Ratings – Available in 100A and 200A versions to meet different project requirements.
- Reliable Electrical Performance – 110kV impulse voltage and 42kV power-frequency withstand voltage for 10-15kV systems.
- Good Anti-Pollution Performance – 250mm creepage distance supports reliable performance in polluted and humid environments.
- Robust Mechanical Design – Compact and durable construction suitable for outdoor overhead line installations.
- Customisable – Dimensions, electrical ratings, mounting configurations, and fuse link options can be tailored upon request.
- Cost-Effective – High performance with competitive project cost.
- Versatile – Suitable for primary overhead feeder lines, taps, and distribution transformer protection.
SFC1-11KV USA Type Cutout Fuse Customisation Options
The SFC1-11KV USA Type cutout fuse can be customised to meet specific project requirements, including:
- Rated voltage
- Rated current
- Breaking current
- Impulse voltage
- Power-frequency withstand voltage
- Creepage distance
- Dimensions and tolerances
- Mounting configurations
- Fuse link options
- Engineering drawings and technical documentation
For customisation requests, please visit Custom Fuse Solutions or Contact Us.
About the SFC1-11KV USA Type Cutout Fuse Manufacturer
The SFC1-11KV USA Type Cutout Fuse can be supplied by leading Chinese manufacturers, subject to confirmation for this model. Manufacturers typically hold ISO 9001 certification and produce cutout fuses in accordance with IEC, IEEE, ANSI, GB, DIN, and AS standards where applicable. All products undergo rigorous electrical and mechanical testing before shipment.
Model: SFC1-11KV USA Type
Rated Voltage: 10-15 kV
Rated Current: 100 A / 200 A
Breaking Current: 10000 A / 12000 A
Standards: To be confirmed / refer to original documentation
External manufacturer quality references:
ISO 9001 Quality Management · IEC · IEEE Standards Association · ANSI
SFC1-11KV USA Type Cutout Fuse FAQ
- What is the SFC1-11KV USA Type Cutout Fuse used for?
It is used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads.
- What is the rated voltage of the SFC1-11KV?
The rated voltage is 10-15 kV.
- What rated current options are available?
The SFC1-11KV is available in 100A and 200A rated current versions.
- What is the breaking current?
The breaking current is 10000A for the 100A version and 12000A for the 200A version.
- What are the impulse voltage and power-frequency withstand voltage?
The impulse voltage is 110kV, and the power-frequency withstand voltage is 42kV.
- What is the creepage distance?
The creepage distance is 250mm.
- What are the weight and dimensions?
The weight is 7kg, and the dimensions are 38.5×34.5×10.5 cm.
- Can the SFC1-11KV be customised?
Yes. Dimensions, electrical ratings, mounting configurations, and fuse link options are customisable upon request.
- What standards apply to the SFC1-11KV?
Applicable standards should be confirmed against the original documentation or with the technical team. IEC, IEEE, ANSI, GB, DIN, and AS standards may be available upon request.
- How can I request a quote or technical drawing?
Please visit Request a Quote or Contact Us for pricing, availability, and engineering drawings.
SFC1-11KV USA Type Cutout Fuse Internal Links
- Product Catalog
- Cutout Fuses
- High Voltage Fuses
- Overhead Line Protection
- Distribution Transformer Protection
- Overhead Feeder Protection
- Custom Fuse Solutions
- SFC1-11KV Datasheet
- Request a Quote
- Certification & Compliance
- Contact Us