• BONLE (FUJIAN) INSULATOR CO., LTD.
  • Office: 3#, 2 Period, Vanke V-City, Cangshan District, Fuzhou, Fujian, China
  • Factory: Baiting, Baizhong, Minqing, Fuzhou, Fujian, China
Facebook X-twitter Youtube Linkedin Instagram Pinterest
BONLE logo
  • Home
  • Products
    • Insulators
      • Porcelain (Ceramic) Insulators
        • Suspension Insulators
        • Pin Insulators
        • Line Post Insulators
        • Pin Post Insulators
        • Station Post Insulators
        • Hollow Insulators / Bushings
        • Long Rod Insulators
        • Low Voltage Insulators
      • Toughened Glass Insulators
        • Standard Profile
        • Fog / Anti-Pollution Profile
        • Aerodynamic Profile
        • DC Insulators
      • Composite (Polymer, Silicone) Insulators
        • Suspension / Tension
        • Line Post
        • Station Post
        • Hollow Insulators
        • Long-Rod Suspension
        • Insulation Cross-arm
      • HDPE Insulators
    • Insulator Components and Hardware
      • Insulator Steel Pins (Spindles)
      • Insulator Steel Caps
      • Line Hardware
    • Accessories
      • Anchor Rods
      • Bushings
      • Cross-arms
      • Guy Wires
    • Power T&D Equipment
      • Cables
      • Circuit Breakers
      • Cutout Fuses
      • Transformers
    • Electrical and Lighting
      • Ceramic (Porcelain) Lamp Holders / Lampholders
      • Lighting Fixtures
    • By Standard
      • ANSI
      • IEC
      • BS
      • AS-NZS
      • GB-JB
      • GOST
    • By Certification
      • KEMA
      • VDE
    • All Products
  • About Us
  • Services
    • Exported to Markets
      • America (USA)
      • Australia
      • New Zealand
      • Colombia
      • Chile
      • Peru
      • Mexico
      • Malaysia
    • Project for Home & Abroad
    • Factory Acceptance Test (FAT)
    • Factory Audit & Review
  • DOWNLOADS
    • Drawings
      • Porcelain (Ceramic) Insulators
      • Toughened Glass Insulators
      • Composite (Polymer, Silicone) Insulators
    • Factory Test Reports
    • Sales Record (Reference)
    • Type Test Report (3rd Party)
    • Standard
  • CERTIFICATES
  • Blog
  • contact us
  • Home
  • Products
    • Insulators
      • Porcelain (Ceramic) Insulators
        • Suspension Insulators
        • Pin Insulators
        • Line Post Insulators
        • Pin Post Insulators
        • Station Post Insulators
        • Hollow Insulators / Bushings
        • Long Rod Insulators
        • Low Voltage Insulators
      • Toughened Glass Insulators
        • Standard Profile
        • Fog / Anti-Pollution Profile
        • Aerodynamic Profile
        • DC Insulators
      • Composite (Polymer, Silicone) Insulators
        • Suspension / Tension
        • Line Post
        • Station Post
        • Hollow Insulators
        • Long-Rod Suspension
        • Insulation Cross-arm
      • HDPE Insulators
    • Insulator Components and Hardware
      • Insulator Steel Pins (Spindles)
      • Insulator Steel Caps
      • Line Hardware
    • Accessories
      • Anchor Rods
      • Bushings
      • Cross-arms
      • Guy Wires
    • Power T&D Equipment
      • Cables
      • Circuit Breakers
      • Cutout Fuses
      • Transformers
    • Electrical and Lighting
      • Ceramic (Porcelain) Lamp Holders / Lampholders
      • Lighting Fixtures
    • By Standard
      • ANSI
      • IEC
      • BS
      • AS-NZS
      • GB-JB
      • GOST
    • By Certification
      • KEMA
      • VDE
    • All Products
  • About Us
  • Services
    • Exported to Markets
      • America (USA)
      • Australia
      • New Zealand
      • Colombia
      • Chile
      • Peru
      • Mexico
      • Malaysia
    • Project for Home & Abroad
    • Factory Acceptance Test (FAT)
    • Factory Audit & Review
  • DOWNLOADS
    • Drawings
      • Porcelain (Ceramic) Insulators
      • Toughened Glass Insulators
      • Composite (Polymer, Silicone) Insulators
    • Factory Test Reports
    • Sales Record (Reference)
    • Type Test Report (3rd Party)
    • Standard
  • CERTIFICATES
  • Blog
  • contact us
SFC2-11KV Nigeria Type Cutout Fuse
Home / By Standard / IEC

SFC2-11KV Nigeria Type Cutout Fuse – 10-15kV High-Voltage Overhead Line Protection Solution

  • SFC4-24KV Indonesia Type Cutout Fuse
  • SFC1-11KV USA Type Cutout Fuse
Add to quote loading
Categories: All Products, By Standard, Cutout Fuses, GB-JB, IEC, Power T&D Equipment Tags: 10-15kV fuse cutout, 100A cutout fuse, 110kV impulse voltage, 200A cutout fuse, 340mm creepage distance, 40kV withstand voltage, 6000A breaking current, 8000A breaking current, Cutout Fuse SFC2-11KV, distribution transformer protection, drop-out fuse, high voltage fuse cutout, Nigeria Type cutout fuse, overhead feeder protection, porcelain cutout fuse, SFC2-11KV Nigeria Type
  • SFC4-24KV Indonesia Type Cutout Fuse
  • SFC1-11KV USA Type Cutout Fuse
  • Description

H1 SFC2-11KV Nigeria Type Cutout Fuse – 10-15kV High-Voltage Overhead Line Protection Solution

In electrical distribution, a fuse cutout or cut-out fuse is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads.

 

The SFC2-11KV Nigeria Type is designed for 10-15kV class systems and is available in 100A and 200A rated current versions.

 

It provides reliable electrical performance, high breaking capacity, and flexible customisation for various distribution project requirements.

 

The SFC2-11KV Nigeria Type features a breaking current of 6000A for the 100A version and 8000A for the 200A version.

 

It offers an impulse voltage of 110kV, power-frequency withstand voltage of 40kV, creepage distance of 340mm, weight of 7.5kg, and dimensions of 49x27x11 cm.

 

We make available these fuses in varied specifications to meet the clients’ different preferences in an efficient manner.

 

All dimensions, electrical ratings, mounting configurations, and fuse link options are customizable upon request.

 

For complete engineering drawings or specific tolerances, please refer to the original documentation or contact our technical team.

 

Related internal pages:
Cutout Fuses · High Voltage Fuses · Distribution Transformer Protection · Overhead Feeder Protection · SFC2-11KV Datasheet · Request a Quote · Contact Us

 

External reference:
Fuse cutout – Wikipedia · Fuse (electrical) – Wikipedia · IEC – International Electrotechnical Commission · IEEE Standards Association · ANSI

 

SFC2-11KV Nigeria Type Cutout Fuse Technical Specifications

Specification SFC2-11KV SFC2-11KV
Rated Voltage (kV) 10-15 10-15
Rated Current (A) 100 200
Breaking Current (A) 6000 8000
Impulse Voltage (kV) 110 110
Power-frequency Withstand Voltage (kV) 40 40
Creepage Distance (mm) 340 340
Weight (kg) 7.5 7.5
Dimensions (cm) 49x27x11 49x27x11

 

SFC2-11KV Nigeria Type Cutout Fuse Key Features

  • Fuse and Switch Combination – Combines the functions of a fuse and a switch for primary overhead feeder lines and taps.
  • Distribution Transformer Protection – Protects distribution transformers from current surges and overloads.
  • High Breaking Capacity – Breaking current of 6000A for the 100A version and 8000A for the 200A version.
  • Reliable Electrical Performance – Rated for 10-15kV systems with 110kV impulse voltage and 40kV power-frequency withstand voltage.
  • Good Anti-Pollution Performance – 340mm creepage distance supports reliable operation in normal and polluted environments.
  • Robust Construction – Designed for outdoor installation with a weight of 7.5kg and dimensions of 49x27x11 cm.
  • Easy Installation – Nigeria Type design suitable for standard mounting methods on overhead line structures.
  • Customizable Design – Dimensions, electrical ratings, mounting configurations, and fuse link options can be customised upon request.
  • Reliable and Low Maintenance – Engineered for long-term operation with regular visual inspection and cleaning typically sufficient.

 

SFC2-11KV Nigeria Type Cutout Fuse Application Scenarios

The SFC2-11KV Nigeria Type cutout fuse is suitable for:

  • Primary overhead feeder lines and taps
  • Distribution transformer protection
  • 10-15kV class overhead distribution networks
  • AC overhead power lines
  • Pole-mounted installations on wooden, reinforced concrete, and metal poles
  • Power distribution networks in normal and polluted areas
  • Rural and urban distribution systems
  • Industrial and commercial power distribution
  • Areas exposed to current surges and overloads
  • Vertical or horizontal mounting, subject to project design

 

Related internal pages:
Overhead Line Protection · Distribution Line Protection · Transformer Protection · Custom Fuse Solutions

 

SFC2-11KV Nigeria Type Cutout Fuse Standards Compliance

Standard Description
To be confirmed Please refer to original documentation or contact technical team for applicable standard compliance.
NIS Nigerian Industrial Standard may be available upon request, if applicable.
IEC Additional standards may be available upon request.
IEEE Additional standards may be available upon request.
ANSI Additional standards may be available upon request.
GB / DIN / AS Additional standards may be available upon request.

 

External standards references:
NIS / Standards Organisation of Nigeria · IEC · IEEE Standards Association · ANSI · DIN · Standards Australia

 

Why Choose SFC2-11KV Nigeria Type Cutout Fuse for Your Power Grid?

  • High Breaking Capacity – 6000A/8000A breaking current provides reliable protection against current surges and overloads.
  • Dual Current Ratings – Available in 100A and 200A versions to meet different project requirements.
  • Reliable Electrical Performance – 110kV impulse voltage and 40kV power-frequency withstand voltage for 10-15kV systems.
  • Good Anti-Pollution Performance – 340mm creepage distance supports reliable performance in polluted and humid environments.
  • Robust Mechanical Design – Compact and durable construction suitable for outdoor overhead line installations.
  • Customizable – Dimensions, electrical ratings, mounting configurations, and fuse link options can be tailored upon request.
  • Cost-Effective – High performance with competitive project cost.
  • Versatile – Suitable for primary overhead feeder lines, taps, and distribution transformer protection.

 

SFC2-11KV Nigeria Type Cutout Fuse Customisation Options

The SFC2-11KV Nigeria Type cutout fuse can be customised to meet specific project requirements, including:

  • Rated voltage
  • Rated current
  • Breaking current
  • Impulse voltage
  • Power-frequency withstand voltage
  • Creepage distance
  • Dimensions and tolerances
  • Mounting configurations
  • Fuse link options
  • Engineering drawings and technical documentation

 

For customisation requests, please visit Custom Fuse Solutions or Contact Us.

 

About the SFC2-11KV Nigeria Type Cutout Fuse Manufacturer

The SFC2-11KV Nigeria Type Cutout Fuse can be supplied by leading Chinese manufacturers, subject to confirmation for this model. Manufacturers typically hold ISO 9001 certification and produce cutout fuses in accordance with IEC, IEEE, ANSI, GB, DIN, and AS standards where applicable. All products undergo rigorous electrical and mechanical testing before shipment.

Model: SFC2-11KV Nigeria Type
Rated Voltage: 10-15 kV
Rated Current: 100 A / 200 A
Breaking Current: 6000 A / 8000 A
Standards: To be confirmed / refer to original documentation

External manufacturer quality references:
ISO 9001 Quality Management · IEC · IEEE Standards Association · ANSI

 

SFC2-11KV Nigeria Type Cutout Fuse FAQ

  1. What is the SFC2-11KV Nigeria Type Cutout Fuse used for?

It is used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads.

 

  1. What is the rated voltage of the SFC2-11KV?

The rated voltage is 10-15 kV.

 

  1. What rated current options are available?

The SFC2-11KV is available in 100A and 200A rated current versions.

 

  1. What is the breaking current?

The breaking current is 6000A for the 100A version and 8000A for the 200A version.

 

  1. What are the impulse voltage and power-frequency withstand voltage?

The impulse voltage is 110kV, and the power-frequency withstand voltage is 40kV.

 

  1. What is the creepage distance?

The creepage distance is 340mm.

 

  1. What are the weight and dimensions?

The weight is 7.5kg, and the dimensions are 49x27x11 cm.

 

  1. Can the SFC2-11KV be customised?

Yes. Dimensions, electrical ratings, mounting configurations, and fuse link options are customizable upon request.

 

  1. What standards apply to the SFC2-11KV?

Applicable standards should be confirmed against the original documentation or with the technical team. NIS, IEC, IEEE, ANSI, GB, DIN, and AS standards may be available upon request.

 

  1. How can I request a quote or technical drawing?

Please visit Request a Quote or Contact Us for pricing, availability, and engineering drawings.

 

SFC2-11KV Nigeria Type Cutout Fuse Internal Links

  • Product Catalog
  • Cutout Fuses
  • High Voltage Fuses
  • Overhead Line Protection
  • Distribution Transformer Protection
  • Overhead Feeder Protection
  • Custom Fuse Solutions
  • SFC2-11KV Datasheet
  • Request a Quote
  • Certification & Compliance
  • Contact Us

 

SFC2-11KV Nigeria Type Cutout Fuse External Links

  • Fuse cutout – Wikipedia
  • Fuse (electrical) – Wikipedia
  • IEC – International Electrotechnical Commission
  • IEEE Standards Association
  • ANSI
  • ISO 9001 Quality Management
  • DIN
  • Standards Australia
  • Standards Organisation of Nigeria

Related products

ANSI 52-4 Suspension Insulators
Quick View

All Products

Premium ANSI 52-4 Insulator — Durable 70kN Porcelain Suspension Insulator for 69-138kV Lines

SFC5-33KV Thailand Type Cutout Fuse
Quick View

All Products

SFC5-33KV Thailand Type Cutout Fuse – 33kV High-Voltage Overhead Line Protection Solution

ANSI 55-2 Pin Insulators
Quick View

All Products

Premium ANSI 55-2 Insulator | Durable Pin-Type Porcelain Insulator for Distribution Lines

ANSI 56-3 Pin Insulators
Quick View

All Products

Premium ANSI 56-3 Insulator | Durable Pin-Type Porcelain Insulator for Distribution Lines

SFC1-11KV USA Type Cutout Fuse
Quick View

All Products

SFC1-11KV USA Type Cutout Fuse | 10-15kV 100A/200A High Voltage Fuse Cutout

Cutout Porcelain Insulator
Quick View

All Products

Cutout Porcelain Insulator — Customizable Design, Brown or Gray Glaze, Reliable Distribution Overcurrent Protection, IEC 60383

ANSI 55-6 Pin Insulators
Quick View

All Products

Premium ANSI 55-6 Insulator | Durable Pin-Type Porcelain Insulator for Distribution Lines

ANSI 55-5 Pin Insulators
Quick View

All Products

Premium ANSI 55-5 Insulator | Durable Pin-Type Porcelain Insulator for Distribution Lines

Logo of Bonle (Fujian) Insulator Co., Ltd.
  • Leading China Insulator Manufacturer since 1992.

Products

  • Porcelain Insulators
  • Glass Insulators
  • Composite Insulators

Company

  • About Us
  • Factory Audit
  • Certificates
  • Contact Us

Resources

  • Download Catalog
  • Type Test Reports
  • Blog

Get in Touch

Envelope
Whatsapp
Weixin
Request a Quote

Useful Links

  • INMR
  • ANSI
  • IEC
Facebook X-twitter Youtube Linkedin Instagram Pinterest

© 2026 Bonle (Fujian) Insulator Co., Ltd. - All rights reserved

  • Home
  • Products
    • Insulators
      • Porcelain (Ceramic) Insulators
        • Suspension Insulators
        • Pin Insulators
        • Line Post Insulators
        • Pin Post Insulators
        • Station Post Insulators
        • Hollow Insulators / Bushings
        • Long Rod Insulators
        • Low Voltage Insulators
      • Toughened Glass Insulators
        • Standard Profile
        • Fog / Anti-Pollution Profile
        • Aerodynamic Profile
        • DC Insulators
      • Composite (Polymer, Silicone) Insulators
        • Suspension / Tension
        • Line Post
        • Station Post
        • Hollow Insulators
        • Long-Rod Suspension
        • Insulation Cross-arm
      • HDPE Insulators
    • Insulator Components and Hardware
      • Insulator Steel Pins (Spindles)
      • Insulator Steel Caps
      • Line Hardware
    • Accessories
      • Anchor Rods
      • Bushings
      • Cross-arms
      • Guy Wires
    • Power T&D Equipment
      • Cables
      • Circuit Breakers
      • Cutout Fuses
      • Transformers
    • Electrical and Lighting
      • Ceramic (Porcelain) Lamp Holders / Lampholders
      • Lighting Fixtures
    • By Standard
      • ANSI
      • IEC
      • BS
      • AS-NZS
      • GB-JB
      • GOST
    • By Certification
      • KEMA
      • VDE
    • All Products
  • About Us
  • Services
    • Exported to Markets
      • America (USA)
      • Australia
      • New Zealand
      • Colombia
      • Chile
      • Peru
      • Mexico
      • Malaysia
    • Project for Home & Abroad
    • Factory Acceptance Test (FAT)
    • Factory Audit & Review
  • DOWNLOADS
    • Drawings
      • Porcelain (Ceramic) Insulators
      • Toughened Glass Insulators
      • Composite (Polymer, Silicone) Insulators
    • Factory Test Reports
    • Sales Record (Reference)
    • Type Test Report (3rd Party)
    • Standard
  • CERTIFICATES
  • Blog
  • contact us
  • Login

Login

Lost your password?

Send Enquiry

  • →
  • WhatsApp
  • WeChat: