• BONLE (FUJIAN) INSULATOR CO., LTD.
  • Office: 3#, 2 Period, Vanke V-City, Cangshan District, Fuzhou, Fujian, China
  • Factory: Baiting, Baizhong, Minqing, Fuzhou, Fujian, China
Facebook X-twitter Youtube Linkedin Instagram Pinterest
BONLE logo
  • Home
  • Products
    • Insulators
      • Porcelain (Ceramic) Insulators
        • Suspension Insulators
        • Pin Insulators
        • Line Post Insulators
        • Pin Post Insulators
        • Station Post Insulators
        • Hollow Insulators / Bushings
        • Long Rod Insulators
        • Low Voltage Insulators
      • Toughened Glass Insulators
        • Standard Profile
        • Fog / Anti-Pollution Profile
        • Aerodynamic Profile
        • DC Insulators
      • Composite (Polymer, Silicone) Insulators
        • Suspension / Tension
        • Line Post
        • Station Post
        • Hollow Insulators
        • Long-Rod Suspension
        • Insulation Cross-arm
      • HDPE Insulators
    • Insulator Components and Hardware
      • Insulator Steel Pins (Spindles)
      • Insulator Steel Caps
      • Line Hardware
    • Accessories
      • Anchor Rods
      • Bushings
      • Cross-arms
      • Guy Wires
    • Power T&D Equipment
      • Cables
      • Circuit Breakers
      • Cutout Fuses
      • Transformers
    • Electrical and Lighting
      • Ceramic (Porcelain) Lamp Holders / Lampholders
      • Lighting Fixtures
    • By Standard
      • ANSI
      • IEC
      • BS
      • AS-NZS
      • GB-JB
      • GOST
    • By Certification
      • KEMA
      • VDE
    • All Products
  • About Us
  • Services
    • Exported to Markets
      • America (USA)
      • Australia
      • New Zealand
      • Colombia
      • Chile
      • Peru
      • Mexico
      • Malaysia
    • Project for Home & Abroad
    • Factory Acceptance Test (FAT)
    • Factory Audit & Review
  • DOWNLOADS
    • Drawings
      • Porcelain (Ceramic) Insulators
      • Toughened Glass Insulators
      • Composite (Polymer, Silicone) Insulators
    • Factory Test Reports
    • Sales Record (Reference)
    • Type Test Report (3rd Party)
    • Standard
  • CERTIFICATES
  • Blog
  • contact us
  • Home
  • Products
    • Insulators
      • Porcelain (Ceramic) Insulators
        • Suspension Insulators
        • Pin Insulators
        • Line Post Insulators
        • Pin Post Insulators
        • Station Post Insulators
        • Hollow Insulators / Bushings
        • Long Rod Insulators
        • Low Voltage Insulators
      • Toughened Glass Insulators
        • Standard Profile
        • Fog / Anti-Pollution Profile
        • Aerodynamic Profile
        • DC Insulators
      • Composite (Polymer, Silicone) Insulators
        • Suspension / Tension
        • Line Post
        • Station Post
        • Hollow Insulators
        • Long-Rod Suspension
        • Insulation Cross-arm
      • HDPE Insulators
    • Insulator Components and Hardware
      • Insulator Steel Pins (Spindles)
      • Insulator Steel Caps
      • Line Hardware
    • Accessories
      • Anchor Rods
      • Bushings
      • Cross-arms
      • Guy Wires
    • Power T&D Equipment
      • Cables
      • Circuit Breakers
      • Cutout Fuses
      • Transformers
    • Electrical and Lighting
      • Ceramic (Porcelain) Lamp Holders / Lampholders
      • Lighting Fixtures
    • By Standard
      • ANSI
      • IEC
      • BS
      • AS-NZS
      • GB-JB
      • GOST
    • By Certification
      • KEMA
      • VDE
    • All Products
  • About Us
  • Services
    • Exported to Markets
      • America (USA)
      • Australia
      • New Zealand
      • Colombia
      • Chile
      • Peru
      • Mexico
      • Malaysia
    • Project for Home & Abroad
    • Factory Acceptance Test (FAT)
    • Factory Audit & Review
  • DOWNLOADS
    • Drawings
      • Porcelain (Ceramic) Insulators
      • Toughened Glass Insulators
      • Composite (Polymer, Silicone) Insulators
    • Factory Test Reports
    • Sales Record (Reference)
    • Type Test Report (3rd Party)
    • Standard
  • CERTIFICATES
  • Blog
  • contact us
ANSI 57 Series Line Post Insulators
Home / By Standard / ANSI

ANSI 57 Series Porcelain Line Post Insulators — Technical Comparison (12.5kN Class)

  • ANSI 52 Series Suspension Insulators
  • ANSI 57-5 Line Post Insulators
Add to quote loading
Categories: All Products, ANSI, By Standard, Insulators, Line Post Insulators, Porcelain (Ceramic) Insulators Tags: ANSI 57 series insulator, ANSI 57-1, ANSI 57-2, ANSI 57-3, ANSI 57-4, ANSI 57-5, ANSI 57-6, ANSI C29.7 insulator, cantilever strength, creepage distance, distribution insulator, flashover voltage, high voltage line post insulator, line post porcelain insulator, overhead line insulator, radio influence voltage, wet-process porcelain
  • ANSI 52 Series Suspension Insulators
  • ANSI 57-5 Line Post Insulators
  • Description

H1: ANSI 57 Series Line Post Insulators Complete Guide for 57‑1 to 57‑6 Line Post Porcelain Insulators (11 kV – 69 kV)

ANSI 57 Series Line Post insulators products are six classes of wet‑process porcelain line post insulators – 57‑1, 57‑2, 57‑3, 57‑4, 57‑5, and 57‑6 – engineered for overhead transmission and distribution lines from 11 kV to 69 kV.

 

Manufactured to ANSI C29.7 standards, these ANSI 57 series line post insulators units feature solid‑core construction with creepage distances ranging from 356 mm (57‑1) to 1,364 mm (57‑6), providing reliable performance from light to heavy pollution environments.

 

Available in Tie‑Top and Line Post styles, with long‑stud (L) and short‑stud (S) options, the ANSI 57 series insulator family is widely used across North American and ANSI‑adopting grids.

 

Whether for substation bus supports, rural distribution, or industrial power systems, this ANSI 57 series insulator range delivers consistent electrical insulation, mechanical robustness, and decades of service life.

 

H2: ANSI 57 Series Line Post Insulators Technical Specifications (57‑1 to 57‑6)

The table below compiles all key dimensional, electrical, and mechanical parameters for each ANSI 57 series insulator class, based on manufacturer datasheets and ANSI/NEMA C29.7.

Parameter Unit 57‑1 57‑2 57‑3 57‑4 57‑5 57‑6
ANSI Class — 57‑1 57‑2 57‑3 57‑4 57‑5 57‑6
Figure No. — 1 2 3 4 5 6
With Long Stud — 57‑1L 57‑2L 57‑3L 57‑4L 57‑5L 57‑6L
With Short Stud — 57‑1S 57‑2S 57‑3S 57‑4S 57‑5S 57‑6S
Creepage / Leakage Distance mm 356 559 737 1015 1145 1364
Dry Arcing Distance mm 165 241 311 368 438 489
Cantilever Strength kN 12.5 12.5 12.5 12.5 12.5 12.5
Power Freq. – Dry Flashover kV 70 100 125 140 160 180
Power Freq. – Wet Flashover kV 50 70 95 110 130 150
Critical Impulse Flashover (+) kV 120 160 200 230 265 300
Critical Impulse Flashover (‑) kV 155 205 260 340 380 —
RIV Test Voltage (to ground) kV 15 22 30 44 44 44
Max. RIV at 1,000 kHz μV 100 100 200 200 200 200
Net Weight kg 5 9.8 12 16 18 20.5

All models: Standard ANSI C29.7 · Solid core wet‑process porcelain · Glaze: Brown / Grey

Source: Manufacturer catalogue

 

H2: ANSI 57 Series Line Post Insulators Material & Construction

Every ANSI 57 series insulator is produced from high‑grade electrical porcelain using the wet‑process method, fired at high temperatures to achieve maximum density, mechanical strength, and near‑zero porosity.

 

The body is coated with a smooth, hard glaze (brown or grey) that provides excellent self‑cleaning properties, tracking resistance, and erosion resistance. The solid‑core design ensures stable performance under extreme temperature cycling and vibration.

 

Metal fittings are made of malleable iron, ductile iron, or steel, with ferrous components hot‑dip galvanized per ASTM A153. The ANSI 57 series insulator operates reliably in high‑voltage environments and harsh climates, including high altitudes and heavy‑pollution areas.

 

For more on porcelain manufacturing standards, visit the International Electrotechnical Commission (IEC).

 

H2: ANSI 57 Series Line Post Insulators Applications & Installation

The ANSI 57 series insulator is the preferred choice for:

 

High‑voltage overhead transmission lines (11 kV to 69 kV)

 

Urban and rural distribution networks

 

Substation bus supports and riser poles

 

Industrial power distribution requiring dependable insulation

 

Heavy‑pollution areas (coastal, industrial, desert) needing extended leakage paths

 

Two stud configurations are available:

 

Long Stud (L) – for extra mounting height

 

Short Stud (S) – for compact installations with standard clearance

 

Installation is simple: mount the insulator on a support structure using the standard stud base. Standardized dimensions ensure full interchangeability with existing ANSI Class 57 hardware. Hot‑stick‑compatible designs for live‑line maintenance are available on request.

 

Explore our full range of suspension insulators and transmission hardware for more options.

 

H2: ANSI 57 Series Line Post Insulators Quality & Performance Advantages

Progressive creepage distance – from 356 mm to 1,364 mm, allowing precise matching to site pollution levels and reducing flashover risk.

 

Superior flashover resilience – dry flashover 70‑180 kV, wet flashover 50‑150 kV, ensuring stable operation in rain, fog, and dew.

 

High impulse withstand – positive‑polarity critical impulse flashover up to 300 kV (57‑6), protecting against lightning and switching surges.

 

Consistent mechanical strength – all models share a uniform 12.5 kN cantilever strength, performing reliably under wind, ice, and conductor tension.

 

Controlled radio interference – RIV values strictly maintained at 100‑200 μV at 1,000 kHz, meeting stringent EMC requirements.

 

Long service life – porcelain resists UV, bird pecking, and scratches, with a service life exceeding 40 years under normal conditions.

 

Each ANSI 57 series insulator undergoes 100% routine electrical and mechanical testing – visual inspection, dimensional checks, cantilever load tests, and high‑voltage withstand tests.

 

Design tests per ANSI C29.7 cover dry/wet flashover, critical impulse flashover, radio influence voltage, and thermal‑mechanical performance. Full test reports and batch traceability are provided. Testing procedures are detailed in ANSI C29.7, published by NEMA.

 

Packaging: each unit is individually packed with foam cushioning and secured in sturdy wooden crates or corrugated cartons. Flexible shipping options (FOB, CIF, EXW) with lead times of 15‑30 days.

 

For installation guidance, refer to our insulator string assembly guide.

 

H2: ANSI 57 Series Line Post Insulators Selection Recommendations

Application Environment Recommended Model(s) Key Selection Criteria
Medium voltage distribution (11 kV) 57‑1 356 mm creepage, 70 kV dry flashover, lightweight (5.0 kg)
Medium voltage (15‑24 kV) 57‑2 559 mm creepage, 100 kV dry flashover, 9.8 kg
Medium voltage (24‑34.5 kV) 57‑3 737 mm creepage, 125 kV dry flashover, 12.0 kg
High voltage (34.5‑46 kV) 57‑4 1,015 mm creepage, 140 kV dry flashover, 16.0 kg
High voltage (46‑69 kV) 57‑5 1,145 mm creepage, 160 kV dry flashover, 18.0 kg
Extra‑high voltage / severe pollution 57‑6 1,364 mm creepage, 180 kV dry flashover, max impulse 300 kV, 20.5 kg

 

For detailed datasheets, CAD drawings, or competitive pricing on any ANSI 57 series insulator, please contact our sales team via the inquiry form below. We also offer OEM services and free technical consultation for transmission line design.

 

H2: ANSI 57 Series Line Post Insulators References & Authoritative Resources

For certification, standard compliance, and procurement specifications, refer to:

  1. International Electrotechnical Commission (IEC) – global standards for electrical insulators and porcelain manufacturing.
    👉 IEC Homepage
  2. Full Range of Suspension Insulators – explore our complete product portfolio for transmission and distribution lines.
    👉 Suspension Insulators Collection 
  3. NEMA Standards – official publications covering ANSI C29.7 and related specifications.
    👉 NEMA Store 
  4. Insulator String Assembly Guide – installation best practices, string design, and torque specifications.
    👉 Assembly Guide 

 

For project‑specific inquiries or cross‑referencing to other ANSI line post classes, consult the ANSI/NEMA C29.7 standard document or contact your engineering representative with the above specification table.

Related products

ANSI 56-4 Pin Insulators
Quick View

All Products

Premium ANSI 56-4 Insulator | Durable Pin-Type Porcelain Insulator for Distribution Lines

ANSI 53-2 Spool Insulators
Quick View

All Products

Premium ANSI 53-2 Insulator | Durable Porcelain Spool Insulator for Distribution Lines

ANSI 52-2 Suspension Insulators
Quick View

All Products

Premium ANSI 52-2 Insulator — Durable 67kN Porcelain Suspension Insulator Reliable for Overhead Transmission Lines

ANSI 55-2 Pin Insulators
Quick View

All Products

Premium ANSI 55-2 Insulator | Durable Pin-Type Porcelain Insulator for Distribution Lines

ANSI 53-4 Spool Insulators
Quick View

All Products

Premium ANSI 53-4 Insulator | Durable Porcelain Spool Insulator for Distribution Lines

ANSI 52-6 Suspension Insulators
Quick View

All Products

ANSI 52-6 Insulator — 111kN Porcelain Suspension Insulator for Overhead Transmission Lines

ANSI 52-9A Suspension Insulators
Quick View

All Products

Premium ANSI 52-9A Insulator — Durable 44kN Porcelain Suspension Insulator for Distribution Lines

ANSI 52-1 Suspension Insulators
Quick View

All Products

ANSI 52-1 Porcelain Disc Suspension Insulator for Overhead Transmission Lines

Logo of Bonle (Fujian) Insulator Co., Ltd.
  • Leading China Insulator Manufacturer since 1992.

Products

  • Porcelain Insulators
  • Glass Insulators
  • Composite Insulators

Company

  • About Us
  • Factory Audit
  • Certificates
  • Contact Us

Resources

  • Download Catalog
  • Type Test Reports
  • Blog

Get in Touch

Envelope
Whatsapp
Weixin
Request a Quote

Useful Links

  • INMR
  • ANSI
  • IEC
Facebook X-twitter Youtube Linkedin Instagram Pinterest

© 2026 Bonle (Fujian) Insulator Co., Ltd. - All rights reserved

  • Home
  • Products
    • Insulators
      • Porcelain (Ceramic) Insulators
        • Suspension Insulators
        • Pin Insulators
        • Line Post Insulators
        • Pin Post Insulators
        • Station Post Insulators
        • Hollow Insulators / Bushings
        • Long Rod Insulators
        • Low Voltage Insulators
      • Toughened Glass Insulators
        • Standard Profile
        • Fog / Anti-Pollution Profile
        • Aerodynamic Profile
        • DC Insulators
      • Composite (Polymer, Silicone) Insulators
        • Suspension / Tension
        • Line Post
        • Station Post
        • Hollow Insulators
        • Long-Rod Suspension
        • Insulation Cross-arm
      • HDPE Insulators
    • Insulator Components and Hardware
      • Insulator Steel Pins (Spindles)
      • Insulator Steel Caps
      • Line Hardware
    • Accessories
      • Anchor Rods
      • Bushings
      • Cross-arms
      • Guy Wires
    • Power T&D Equipment
      • Cables
      • Circuit Breakers
      • Cutout Fuses
      • Transformers
    • Electrical and Lighting
      • Ceramic (Porcelain) Lamp Holders / Lampholders
      • Lighting Fixtures
    • By Standard
      • ANSI
      • IEC
      • BS
      • AS-NZS
      • GB-JB
      • GOST
    • By Certification
      • KEMA
      • VDE
    • All Products
  • About Us
  • Services
    • Exported to Markets
      • America (USA)
      • Australia
      • New Zealand
      • Colombia
      • Chile
      • Peru
      • Mexico
      • Malaysia
    • Project for Home & Abroad
    • Factory Acceptance Test (FAT)
    • Factory Audit & Review
  • DOWNLOADS
    • Drawings
      • Porcelain (Ceramic) Insulators
      • Toughened Glass Insulators
      • Composite (Polymer, Silicone) Insulators
    • Factory Test Reports
    • Sales Record (Reference)
    • Type Test Report (3rd Party)
    • Standard
  • CERTIFICATES
  • Blog
  • contact us
  • Login

Login

Lost your password?

Send Enquiry

  • →
  • WhatsApp
  • WeChat: